On this page, we can show you some of the newest products in the industry and provide you with the links to their websites so you can obtain additional information and installation instructions.
Actown • The New Guardian II Transformer - Less is Best 
Less Tripping, Less Sensitivity
-Improved electronic circuitry
-Will not trip due to high voltages on the neutral wire
Less Burn-Outs

-Higher temperature construction
-Reformulated potting compound and higher grade components
Less Troubleshooting

-Simple LED/service bypass mode diagnostics
-Quick, two step procedure determines if the fault is in the secondary or ground circuit
Less Service Models

-With the 25mA self-regulating models, service inventories can be reduced to just two model numbers in each series
Less Hassle

-No polarity for supply connections
-Able to exit service bypass mode without turning off power

Westrim • High Voltage Splice Enclosure

Splices two GTO cables – integral spacer keeps connection in place
Rated for 7500 volt applications, including 15000V mid-point referenced transformer
   installations
Borosillicate glass and metal construction makes it a solid, safe, and long life product.
UV Protected Lexan divider – UL tested for UV & heat resistance
Simplifies installation, improves quality, reduces installation costs! Channel letters are
   fully assembled in the shop with the electrode receptacles installed, tubes mounted,
   wired complete with flex conduit and GTO. At the installation site, the letters are
   mounted to the building and wired to one another using the HVSE. This procedure
  reduces glass breakage.

 


Transco •  Vanguard GFP® "G" Series Transformer


These transformers are UL 2161 Listed. Due to their secondary
   output they are considered inherently safe without secondary
   ground fault protection.
Tri-L.E.D. Sensor Lamp Indicator.
Easy troubleshooting with service button








Lecip • Sentry Transformers
Outdoor Non-weatherproof
UL2161 And 1996 & 1999 NEC Compliance
Secondary Ground Fault Protection
High Resistance to invading noise or surges from the primary
  power
Flashable and Dimmable
LED Diagnostics to provide a visual aid and to monitor the
   transformer operation
Pre mounted Disconnect Switch (on/off rocker switch)
Bypass Switch for easy troubleshooting, it can allow the
   secondary ground fault protection mode to be bypassed for
   about 30 minutes.


 

France • PBKM Transformer

UL2161 Listed Type 3 Neon Power Supply
(Outdoor Non-Weatherproof) 1999 and 2002 NEC Compliant
Secondary Circuit Ground Fault Protection with Auto-Restart

-Detects arcs to ground and disables unit.
-Unit will attempt 2 restarts before tripping off.
-Power Supply can be manually reset if unit trips off.
Open Circuit Protection
-
Detects open circuits in high voltage circuit and disables unit.
-Power Supply can be manually reset if unit trips off.
Operating Range
-30 degrees F to 122 degrees F

Self Adjusting for Line & Load from 1 to 5, 7.5 & 10 kV
30mA Self Adjusting Output
High Power Factor
No Mercury Migration
No Jelly-Beaning
Grounded Mounting Foot
Built-in GTO Fittings for Sleeving
1/2” Conduit Fitting for Primary Wiring

Ventex • “Generation III” UL 2161 Listed Products
Electronic High Output Fluorescent Ballast

Increased mA output
Self-adjusting for Line and Load conditions for uniform intensity
Exclusive cold weather startup circuitry
Simple installation procedures
High power factor
Variety of models to choose from to fit any application

(Note: Ballasts are currently in the design and Beta testing stages)



Standard NeoLite • Glass Housings

100, 200 & 300 Glass Housings
Allanson’s Glass Insulators are manufactured from the finest
 made heat resistant glass; all of our glass housings include a 
 cadmium plated steel ferrule.







Electrobits • Liquidtite connectors

ILS-2000 in line splice connectors are used to insulate and
    splice GTO cables.
   -NOTE: GTO cables must always be covered with GTO sleeving
    and installed in flexible or rigid metallic conduit.
• To be used in dry and damp locations only.
• Must be installed in listed sign bodies or enclosures.
• Note the liquidtite connectors, bonding rings, lock nuts and
   bonding straps

 


France • Electronic Transformer
UL2161 Listed Type 3 Neon Power Supply
(Outdoor Non-Weatherproof) 1999 and 2002 NEC Compliant
Secondary Circuit Ground Fault Protection with Auto-Restart

-Detects arcs to ground and disables unit.
-Unit will attempt 2 restarts before tripping off.
-Power Supply can be manually reset if unit trips off.
Open Circuit Protection
-
Detects open circuits in high voltage circuit and disables unit.
-Power Supply can be manually reset if unit trips off.
Operating Range
-30 degrees F to 122 degrees F


Standard NeoLite • Neon Electrode Receptacle

• The Through Wall Insulators are high quality accessories that are
    widely used by sign makers across the U.S. and Canada.
• Integral mounting flange provides a bonding means for the metal
   backed sign body without requiring a separate bonding conductor.
• Spring assembly facilitates easy GTO cable connection.

 




Electrobits • Liquidtite connectors

• Connector to connect 1/2 inch flexible metallic conduit to the
  transformer enclosure.
• Requires a 1/2 inch knockout.
• Made of die-cast zinc

 

 


France • "Smart Series" Transformers
UL2161 Listed Transformer

• Outdoor, non-weatherproof
• Secondary circuit ground fault protection
• Service switch
• Auto-reset
• Diagnostic LED's for easy troubleshooting







Electrobits • Toggle Switch

• Disconnect weatherproof toggle, boot and dry & damp enclosure
• For Dry and Damp locations
• Compact disconnect switch for use in channel letters and sign
   enclosures.
 • Horizontal or vertical wire exit with moveable knockout plug.

 



Westrim • Boots, Sleeving & GTO Wire
Listed to applicable US and Canadian standards and requirements by Underwriters Laboratories, Inc.® for dry and damp locations
  • Use to insulate straight aligned connections between electrodes and GTO cable
  • Great for portable signs
  • Must be used with GTO Max or GTO Hi-Flex with 373 Sleeving (see Technical Sheet for complete instructions)
  • Non-breakable
  • Fits 13 mm tubing


Transfotec • TFT Octopus System  

• Increases safety by eliminating high voltage through wall structure
• Octobox is a junction box that allows you to connect up to 11
  channel letters with quick-connect plugs.
• No wiring, no high-volt connectors.
• Saves time and money with quicker installations.
• The new Octobox is manufactured to use with the existing system
   (reference page 41 in the Neon Installation Guide)






Electrobits • High Volt Connector  
• HVC 1001 High Volt Connector must be installed through or inside a
   listed sign enclosure.
• GTO cables must be covered with GTO sleeving and installed
   in flexible or rigid metallic conduit

 

 


Westrim • Hand Crimp Tool  
• This tool produces a UL-approved crimp on Westrim's SNI and SNC
   terminals (for info on SNI and SNC terminals see Wiring Accessories
   product group)
• Takes the guesswork out of crimping, regardless of the individual
   installer

 

 


Westrim • Glass Tube Supports  
• Clear silicone coating on cradle grips tubing for easier installation
• Silicone also cushions tubing in transit
• Glass stand-off with brass base and attached tie wires
• Use for mounting neon tubing to sign back or enclosure
• Simple and easy to use
• Other styles and sizes available

 

 


Westrim • Louvers  
• Use for heat ventilation in sign enclosures and boxes to extend life of
   transformers and other sign components
• Made from aluminum sheet (no screen)
• Easy installation: just insert in hole and bend tabs back to secure
• Available in 1", 2", 3" and 4" diameters

 

 

 