Lecip • Sentry Transformers |
|
• Outdoor Non-weatherproof
• UL2161 And 1996 & 1999 NEC Compliance
• Secondary Ground Fault Protection
• High Resistance to invading noise or surges from the primary
power
• Flashable and Dimmable
• LED Diagnostics to provide a visual aid and to monitor the
transformer operation
• Pre mounted Disconnect Switch (on/off rocker switch)
• Bypass Switch for easy troubleshooting, it can allow the
secondary ground fault protection mode to be bypassed for
about 30 minutes.
|
|
France • PBKM Transformer |
|
UL2161 Listed Type 3 Neon Power Supply
(Outdoor Non-Weatherproof) 1999 and 2002 NEC Compliant
Secondary Circuit Ground Fault Protection with Auto-Restart
-Detects arcs to ground and disables unit.
-Unit will attempt 2 restarts before tripping off.
-Power Supply can be manually reset if unit trips off.
Open Circuit Protection
- Detects open circuits in high voltage circuit and disables unit.
-Power Supply can be manually reset if unit trips off.
Operating Range
-30 degrees F to 122 degrees F
|
• Self Adjusting for Line & Load from 1 to 5, 7.5 & 10 kV
• 30mA Self Adjusting Output
• High Power Factor
• No Mercury Migration |
• No Jelly-Beaning
• Grounded Mounting Foot
• Built-in GTO Fittings for Sleeving
• 1/2” Conduit Fitting for Primary Wiring |
|
Ventex • “Generation III” UL 2161 Listed Products |
|
Electronic High Output Fluorescent Ballast
• Increased mA output
• Self-adjusting for Line and Load conditions for uniform intensity
• Exclusive cold weather startup circuitry
• Simple installation procedures
• High power factor
• Variety of models to choose from to fit any application
(Note: Ballasts are currently in the design and Beta testing stages)
|
|
Standard NeoLite • Glass Housings |
|
• 100, 200 & 300 Glass Housings
• Allanson’s Glass Insulators are manufactured from the finest
made heat resistant glass; all of our glass housings include a
cadmium plated steel ferrule.
|
|
Electrobits • Liquidtite connectors |
|
• ILS-2000 in line splice connectors are used to insulate and
splice GTO cables.
-NOTE: GTO cables must always be covered with GTO sleeving
and installed in flexible or rigid metallic conduit.
• To be used in dry and damp locations only.
• Must be installed in listed sign bodies or enclosures.
• Note the liquidtite connectors, bonding rings, lock nuts and
bonding straps
|
|
France • Electronic Transformer |
|
UL2161 Listed Type 3 Neon Power Supply
(Outdoor Non-Weatherproof) 1999 and 2002 NEC Compliant
Secondary Circuit Ground Fault Protection with Auto-Restart
-Detects arcs to ground and disables unit.
-Unit will attempt 2 restarts before tripping off.
-Power Supply can be manually reset if unit trips off.
Open Circuit Protection
- Detects open circuits in high voltage circuit and disables unit.
-Power Supply can be manually reset if unit trips off.
Operating Range
-30 degrees F to 122 degrees F
|
|
Standard NeoLite • Neon Electrode Receptacle |
|
• The Through Wall Insulators are high quality accessories that are
widely used by sign makers across the U.S. and Canada.
• Integral mounting flange provides a bonding means for the metal
backed sign body without requiring a separate bonding conductor.
• Spring assembly facilitates easy GTO cable connection.
|
|
Electrobits • Liquidtite connectors |
|
|
|
• Connector to connect 1/2 inch flexible metallic conduit to the
transformer enclosure.
• Requires a 1/2 inch knockout.
• Made of die-cast zinc
|
|
France • "Smart Series" Transformers |
|
UL2161 Listed Transformer
• Outdoor, non-weatherproof
• Secondary circuit ground fault protection
• Service switch
• Auto-reset
• Diagnostic LED's for easy troubleshooting
|
|
Electrobits • Toggle Switch |
|
• Disconnect weatherproof toggle, boot and dry & damp enclosure
• For Dry and Damp locations
• Compact disconnect switch for use in channel letters and sign
enclosures.
• Horizontal or vertical wire exit with moveable knockout plug.
|
|
Westrim • Boots, Sleeving & GTO Wire |
|
Listed to applicable US and Canadian standards and requirements by Underwriters Laboratories, Inc.® for dry and damp locations
- Use to insulate straight aligned connections between electrodes and GTO cable
- Great for portable signs
- Must be used with GTO Max or GTO Hi-Flex with 373 Sleeving (see Technical Sheet for complete instructions)
- Non-breakable
- Fits 13 mm tubing
|
|
Transfotec • TFT Octopus System |
|
|
• Increases safety by eliminating high voltage through wall structure
• Octobox is a junction box that allows you to connect up to 11
channel letters with quick-connect plugs.
• No wiring, no high-volt connectors.
• Saves time and money with quicker installations.
• The new Octobox is manufactured to use with the existing system
(reference page 41 in the Neon Installation Guide)
|
|
Electrobits • High Volt Connector |
|
|
• HVC 1001 High Volt Connector must be installed through or inside a
listed sign enclosure.
• GTO cables must be covered with GTO sleeving and installed
in flexible or rigid metallic conduit
|
|
Westrim • Hand Crimp Tool |
|
|
• This tool produces a UL-approved crimp on Westrim's SNI and SNC
terminals (for info on SNI and SNC terminals see Wiring Accessories
product group)
• Takes the guesswork out of crimping, regardless of the individual
installer
|
|
Westrim • Glass Tube Supports |
|
|
• Clear silicone coating on cradle grips tubing for easier installation
• Silicone also cushions tubing in transit
• Glass stand-off with brass base and attached tie wires
• Use for mounting neon tubing to sign back or enclosure
• Simple and easy to use
• Other styles and sizes available
|
|
Westrim • Louvers |
|
|
• Use for heat ventilation in sign enclosures and boxes to extend life of
transformers and other sign components
• Made from aluminum sheet (no screen)
• Easy installation: just insert in hole and bend tabs back to secure
• Available in 1", 2", 3" and 4" diameters
|
|
|